How to backtest a satellite-based industrial index against official IP data

Factory chimneys emitting smoke against a winter sunset sky

Official industrial production data lags the month it describes by about three weeks for the first print, and that print is not the number you'll be trading against in six months. The Fed revises G.17 figures for years as survey responses firm up and benchmark data lands from the Census Bureau and other source agencies. So before you backtest a satellite-based activity series against it, decide what you're actually testing: lead time against the first print, or correlation against the fully revised series. Those are different questions and they give different answers.

Pick the vintage you're testing against

A common first pass runs the alternative series against the latest vintage of IP data pulled from FRED today, which already contains two or three years of revisions the market never saw in real time. That tells you whether your index tracks the "true" level of industrial activity, which is a fine question for a research note. It does not tell you whether the index would have called the direction of a print before it dropped. For that you need the real-time data set the Philadelphia Fed and the Fed itself publish, vintage by vintage, so you're comparing your weekly series against what analysts had on their screens the day before release.

If you only run one version of this test, run it against the real-time vintage. The lead-lag story falls apart fast once you swap in revised data, because revisions can move a print by more than the swing you're trying to anticipate.

Match frequency before you match levels

A weekly plant-level series and a monthly sector print don't line up on the calendar, so the first step is deciding how you aggregate. Averaging weekly observations into monthly buckets is the obvious move, but check whether the IP release's reference period matches your bucket boundaries. The Fed's industrial production index uses the calendar month; if your satellite passes cluster irregularly within a month because of weather or revisit gaps, a straight average will understate volatility relative to what a denser series would show. Flag weeks with cloud cover or missed passes explicitly instead of letting a gap default to a flat observation, which biases your correlation toward zero.

Run the backtest on growth rates. Month-over-month or quarter-over-quarter percent changes are what you want to compare, because levels on both series will trend together over any long sample mostly thanks to the shared GDP trend underneath them. Growth rates strip that common drift out and come closer to what you'd trade on.

Set the lead-lag window honestly

Cross-correlate your index against IP growth at leads and lags of zero to three months. A genuine lead shows up as a correlation peak at a positive lag, with your series moving ahead of the print. A peak sitting at lag zero means your series is coincident with the official data, which still has value for nowcasting the current month before the print lands, but it isn't a lead indicator and you shouldn't price it as one.

Hold out a chunk of your sample, at least the most recent four to six quarters, and don't touch it while you're tuning weights for vehicle counts, plume presence, and thermal signal. Fit on the earlier period, then check the held-out window once. If you keep re-running the fit until the out-of-sample period looks good too, you've just moved your overfitting into the test set and the backtest tells you nothing.

Check sector composition, not just the headline number

IP's headline figure blends sectors with very different capital intensity and plant counts, so a plant-level index built from a handful of sites in one sub-sector should be benchmarked against that sub-sector's IP component, not the aggregate. The Fed publishes disaggregated series by NAICS group specifically for this. A mismatch here is the most common reason a backtest looks weak when the underlying signal is fine: you're comparing apples to a fruit basket.

If the lead-lag relationship holds up through a real-time, sector-matched, out-of-sample test, you've got something worth building a position view on ahead of the next print. Industrial Index delivers that weekly CSV series per plant or sector rollup, built from vehicle counts, visible plume presence, and thermal signal at each site, so you can run this backtest yourself before the next release date. Pull a few quarters of the series and see where your lead-lag window lands.

Start a pilot

Back to the blog